Introduction
In the previous article – HDR Transfer Functions, we discussed the transfer functions and how digital images are converted to light levels for display. This article discusses how the same HDR image can be displayed differently by different HDR devices.
What is HDR Tone Mapping?
Tone mapping is the
process of adapting digital signals to appropriate light levels based on the
HDR meta-data. This process is not simply applying the EOTF (Electro-Optical
Transfer Function) on the image data but it is rather trying to map the image
data with the display device capabilities using meta-data information. Since a
broad range of HDR display devices are available in the market, each with their
own Nits (i.e. ‘brightness’) range, correct tone mapping is necessary for a
good user experience. Since the tone mapping is done based on the meta-data in
the video stream, presence of correct meta-data is necessary.
Source footage can
be shot at HDR with best of cameras and then mastered on high-end HDR mastering
systems, but it still need to be displayed optimally on the range of HDR
televisions available in the market. Tone mapping performs an appropriate
brightness mapping of the content to device without significant degradation.
Need for HDR Tone Mapping
Let’s say an image
is shot with peak brightness of 2000 Nits. If it is displayed on a television
with 0-2000 Nits range, the brightness range will be exactly as shot in the raw
footage. However, the results will be different on other devices:
Since tone mapping is a necessary operation to display PQ based HDR content on HDR display devices, the television needs to know the native properties of the content in terms of the brightness range used along with mastering system parameters. This information is conveyed in the form of HDR meta-data. After reading the HDR meta-data, display devices can decide the tone mapping parameters so that the transformed video lies optimally within the display range of the display device.
Next article will discuss the specific
meta-data for HDR-10 and HDR-10+, two different implementation of the HDR. Stay
tuned for that.
Article 2: Transfer
functions
Definitions
cd/m2 – The
candela (cd) is the base unit of luminous intensity in the International System
of Units (SI); that is, luminous power per unit solid angle emitted by a point
light source in a particular direction. A common wax candle emits light with a
luminous intensity of roughly one candela.
Nits – A
non-SI unit used to describe the luminance. 1 Nit = 1 cd/m2.
HDR – High
Dynamic range. It is a technology that improves the brightness & contrast
range in an image (upto 10,000 cd/m2)
SDR – Standard
Dynamic range. It refers to the brightness/contrast range that is usually
available in regular, non-HDR televisions usually with range of upto 100 cd/m2.
This term came into existence after HDR was introduced
WCG – Wide
Color Gamut. Color gamut that offer a wider range of colors than BT.709. DCI-P3
and BT.2020 are examples of WCG offering more realistic representation of
images on display devices.
EOTF – electo-optical
transfer function. A mathematical transfer function that describes how digital
values will be converted to light on a display device.
OETF – optical-electro
transfer function. A mathematical transfer function that describes how the
light values will be converted to digital values typically within cameras.
OOTF – opto-optical
transfer function. This transfer function compensates for the difference in
tonal perception between the environment of the camera and that of the display.
PQ – PQ
(or Perceptual Quantizer) is a transfer function devised to represent the wide
brightness range (upto 10,000 Nits) in HDR devices.
HLG – HLG
(or Hybrid Log Gamma) is a transfer function devised to represent the wide
brightness range in HDR devices. HLG is quite compatible with existing SDR
devices in the SDR range.